WIFI REMOTE THERMOSTAT HIGH AND LOW TEMPERATURE ALARM

$19.90

WIFI remote thermostat
Heating / cooling high and low temperature alarm
WeChat notification Email notification Operation log Cloud record

Tags:

WIFI remote thermostat

Heating / cooling high and low temperature alarm

WeChat notification Email notification Operation log Cloud record

1.1 Automatic mode function description
1) First select heating mode/cooling mode.

2) set the temperature and return difference, if you need to delay the start, then set the next delayed start time

3) If you need to set the high and low temperature alarm, set the high and low temperature alarm threshold by yourself

1.2 Heating mode description
When the detection temperature (current temperature) ≤ set temperature – return difference temperature, the relay is on and the heating equipment begins to work.

When the detection temperature (current temperature) ≥ the set temperature, the relay is disconnected, and the heating equipment stops working.

Example: set temperature 30℃, return difference temperature 5℃.

when the temperature 20 ℃ ≤ 25 ℃ (30 – 5 = 25), the relay suction to start heating, when the temperature reaches 30 ℃ ≥ set temperature 30 ℃, the relay disconnected, stop heating.

1.3 Cooling mode description
when the detection temperature (current temperature) ≥ set temperature + return difference temperature, the relay conducts and the refrigeration equipment begins to work.

When the detection temperature (current temperature) ≤ the set temperature, the relay is disconnected and the refrigeration equipment stops working.

Example: set the temperature 30 ℃, the return difference temperature 5 ℃.

When the temperature 36 ℃ ≥ 35 ℃ (30 + 5 = 35), the relay suction to start cooling, when the temperature reaches 30 ℃ ≤ set temperature 30 ℃, the relay disconnected, stop cooling.

1.4 Delayed start function description
After a heating/cooling process is over, how long the delay (unit: seconds) to allow the next heating/cooling.

1.5 Temperature correction function
the system works for a long time, deviations may occur, corrected by this function, the current temperature = measured temperature + calibration value.

1.6 High and low temperature alarm function
Buzzer on and off: when turned on, the buzzer will sound after the alarm is turned on, and the buzzer will stop sounding after the button is pressed.

High temperature alarm: after turning on the high temperature alarm, the relay will be disconnected after the current temperature is higher than the high temperature alarm temperature.

Low temperature alarm: After the low temperature alarm is turned on, the relay will be disconnected after the current temperature is lower than the low temperature alarm temperature.

1.7 Emergency brake function (emergency stop function)
After opening the emergency stop, the relay will be disconnected no matter what state it is in; after the emergency stop is closed, the relay will return to its normal state.

1.8 Whether the product can be disconnected and run offline in automatic mode
In automatic mode, when the parameters are set, the product can be disconnected and run offline, and the parameters are not lost in power failure.

1.9 LAN data export function
After clicking “Export”, it will be automatically exported to EXCEL for analysis of temperature data.

2.1 Manual mode function description
Timing, time delay, cycle and pointing can be set in manual mode.

2.2 Description of power-on state setting
Power-on status-On: the relay is activated by default after power-on.

Power-on status-Off: the relay is disconnected by default after power-on.

Power-on status-hold: automatically restore the relay state before power off after power on

2.3 Whether the product can be disconnected and run offline in manual mode
In manual mode, the product can not be disconnected for offline operation.

2.4 Description of other functions in manual mode
Other functions are the same as in auto mode

3. Sharing settings
It can be shared with others, so that multiple people can share one device and all can control its functions.

4.Operation record
Can store all the operation records in the background, power on + timer + button + APP + heating and cooling mode, easy to check the relay action status.

6. Cloud record and upload frequency
Can store temperature data in the background, can set the frequency of log uploading, the fastest can be set to 1 second / strip (default 5 minutes a strip); can query the data of any time period at will, the longest can retain the data within 15 days; later can add the cloud data export function, so that the temperature data for the next step in the analysis.